Product Introduction
The WiFi smoke alarm is produced by using infrared photoelectric sensor with special structure design, reliable MCU, and SMT chip processing technology.
It is characterized by high sensitivity, stability and reliability, low power consumption, beauty, durability, and easy-to-use. It is suitable for smoke detection in factories, homes, stores, machine rooms, warehouses and other places.
It is not suitable for use in the following places:
(1) Places with smoke retention under normal conditions.
(2) Places with heavy dust, water mist, steam, oil mist pollution and corrosive gas.
(3) Places with relative humidity greater than 95%.
(4) Places with ventilation speed greater than 5m/s.
(5) The product cannot be installed in the corner of the building.
The alarm adopts a photoelectric sensor with a special structure design and a reliable MCU, which can effectively detect the smoke generated in the initial smoldering stage or after the fire. When the smoke enters the alarm, the light source will produce scattered light, and the receiving element will feel the light intensity (there is a certain linear relationship between the received light intensity and the smoke concentration).
The alarm will continuously collect, analyze and judge the field parameters. When it is confirmed that the light intensity of the field data reaches the predetermined threshold, the red LED light will light up and the buzzer will start to alarm.
When the smoke disappears, the alarm will automatically return to the normal working state.
Key Specifications
Model No. | S100B-CR-W(WiFi) |
Working voltage | DC3V |
Decibel | >85dB(3m) |
Alarm current | ≤300mA |
Static current | ≤15μA |
Operation temperature | -10°C~55°C |
Low battery | 2.6±0.1V(≤2.6V WiFi disconnected) |
Relative Humidity | ≤95%RH(40°C ±2°C Non-condensing) |
Alarm LED light | Red |
Output form | Audible and Visual alarm |
WiFi LED Light | Blue |
WiFi RF Power | Max+16dBm@802.11b |
Operating frequency range | 2400-2484MHz |
WiFi Standard | IEEE 802.11b/g/n |
Silent time | About 15 minutes |
APP | Tuya / Smart Life |
Battery model | CR17450 3V |
Battery capacity | about 2500mAh |
Battery life | about 10 years |
N.W. | 135g (Contains battery) |
Standard | EN 14604:2005 |
EN 14604:2005/AC:2008 |
Download the App
Note: This product is compatible with the Tuya Smart App. You can download the tuya app from the Google Play Store.
ISO iPhone: Download "Smart Life" from Google Play.
Android: Download "Smart Life" from app store.
Open the Smart Life app and create a new account.
Register and log in.
Scanning the QR Code Below:
Connection instruction
Press the switch button, you will hear the sound and light reaction. Waiting for 30 seconds before doing the following operations.
Make sure your smartphone connects to the WIFI (only 2.4GHz WIFI is supported) and turn on Bluetooth.
How to set product functions in Tuya app
How to set product functions in Tuya app
Installation Instruction
Operation Instructions
Normal state: The red LED lights up once every 56 seconds.
Fault state: When the battery is less than 2.6V ± 0.1V, the red LED lights up once every 56 seconds, and the alarm emits a "DI" sound, indicating that the battery is low.
Alarm status: When the smoke concentration reaches the alarm value, the red LED light flashes and the alarm emits an alarm sound.
Self-check status: The alarm shall be self-checked regularly. When the button is pressed for about 1 second, the red LED light flashes and the alarm emits alarm sound. After waiting for about 15 seconds, the alarm will automatically return to the normal working state.
Silence state: In the alarm state, press the Test/Hush button, and the alarm will enter the silence state, alarming will stop and the red LED light will flash. After the silencing state is maintained for about 15 minutes, the alarm will automatically exit the silencing state. If there is still smoke, it will alarm again.
Warning: The silencing function is a temporary measure taken when someone needs to smoke or other operations may trigger the alarm.
Common Faults And Solution
Fault | Cause analysis | Solutions |
---|---|---|
False alarm | There is a lot of smoke in the room or water vapor | 1. Remove the alarm from ceiling mount. Reinstall after the smoke and steam are eliminated. 2. Install the smoke alarm in a new location. |
A "DI" sound | Battery is low | Replace the product. |
No alarm or emit "DI" twice | Circuit failure | Discussing with supplier. |
No alarm when press Test/Hush button | The power switch is off | Press the power switch on the bottom of the case. |
Low battery warning: When the product emits a "DI" alarm sound and LED light flash every 56 seconds, it indicates that the battery will be depleted.
The low battery warning status can last about 30 days.